Solutions

APOLLO™ Intracranial Stent
System
APOLLO™ is designed specifically for intracranial atherosclerotic disease (ICAD).
  • Product characteristics
  • Specification parameter
  • Video display
    • APOLLO™ Intracranial Stent System is a balloon mounted stent designed specifically for the treatment of Intracranial Atherosclerotic Disease (ICAD).

      Balanced Flexibility and Recoil Resistance with Unique Cell Design

      The “reinforcing ring” sine wave open cell is designed to maintain stent radial force after deployment.

      The “n”-shaped connecting rod makes the stent more flexible and minimizes stent foreshortening during stent expansion.

      Excellent Deliverability with Rapid Exchange Delivery System

      The delivery system is a rapid exchange balloon dilation catheter with low crossing profile and ultra-short tip, ensuring atraumatic and rapid navigation to distal lesion.

      Semi-compliant Balloon Design Specified for Intracranial Stenosis

      6 atm Nominal Pressure and 12 atm RBP make the dilation procedure both safe and effective for intracranial stenotic lesions.

      Versatility in Size Selection for all types of lesions

      2.5-4 mm diameter and 8-23 mm length specifications to offer versatile treatment options for different lesions.


      NO.

      Stent Diameters(mm)

      Stent Lengths(mm)

      Catheter(Fr)

      Compatibility(Inch)

      A25082.5860.014
      A25102.51060.014
      A25132.51360.014
      A25152.51560.014
      A25182.51860.014
      A27082.75860.014
      A27102.751060.014
      A27132.751360.014
      A27152.751560.014
      A27182.751860.014
      A30083.0860.014
      A30103.01060.014
      A30133.01360.014
      A30153.01560.014
      A30183.01860.014
      A30233.02360.014
      A35083.5860.014
      A35103.51060.014
      A35133.51360.014
      A35153.51560.014
      A35183.51860.014
      A35233.52360.014
      A40084.0860.014
      A40104.01060.014
      A40134.01360.014
      A40154.01560.014
      A40184.01860.014
      A40234.02360.014


    Mobile:

    (86)19542912295

    Contact:

    (86) (21)38954600-55200

    Address:

    1661 Zhangdong Road, Zhangjiang High-tech Park, Pudong New District, Shanghai, PRC

    Fax:

    (21) 50801305

    @Copyright 2012-2023,MicroPort NeuroScientific All rights reserved
    Website record/ license No.:沪ICP备19033024号-3
    The registered trademarks of “微创", "MicroPort"and" " are registered trademarks of Shanghai MicroPort Medical (Group) Co., Ltd . They have been authorized to be used by MicroPort NeuroScientific and no other party shall use such trademarks without prior written permission thereof.

      Copyright©  微信图片_20200506140817.png 沪ICP备19033024号-3

    Privacy policy Legal statement The website is for reference by professionals only